| Hardware Specifications |
|
| Port specifications |
DG-S5360-48GP4X-1440W |
| Fixed service port |
48 x 10/100/1000BASE-T ports, supporting PoE/PoE+ |
| 4 x 1GE/2.5GE/10GE SFP+ ports |
| Module slot |
2 x power module slots |
| Power module |
PA600IP-F |
| PA1000IP-F |
| (supporting mixed insertion) |
| Fixed management port |
1 x RJ45 console port |
| USB |
1 x USB 2.0 port |
|
|
| System specifications |
|
System packet forwarding
rate*1 |
158 Mpps |
| System switching capacity*2 |
211 Gbps |
| CPU |
Dual-core CPU, each core with the clock speed of 1.0 GHz |
| Real-time clock (RTC) |
Supported |
| BootROM |
16 MB (storing boot software for 1+1 boot redundancy) |
| Flash memory |
512 MB |
| Memory |
1GB DDR4 |
| Switch buffer |
4 MB |
| Number of MAC addresses |
16000 |
| ARP table size |
4000 |
| ND table size |
4000 |
| Number of IPv4 unicast routes |
6000 |
Number of IPv4 multicast
routes |
1000 |
| Number of IPv6 unicast routes |
2000 |
Number of IPv6 multicast
routes |
750 |
| Number of ACEs |
Ingress: 1,750 |
| Egress: 800 |
| Number of IGMP groups |
1000 |
| Number of MLD groups |
750 |
| Number of VSU members |
8 |
| *1 means the system’s packet forwarding rate. |
| *2 means the system’s switching capacity. |
|
|
| Power supply and consumption |
|
| Power supply |
2 x pluggable power modules |
| Power module redundancy |
Only when the PoE load of the whole device is less than PoE output power of single power supply and dual power supplies are used, redundancy is supported. |
| Power input |
DG-PA600I-P-F (AC input): |
· Rated input voltage: 100 V
AC to 240 V AC, 50/60 Hz |
· Maximum input voltage: 90 V
AC to 264 V AC, 47 Hz to 63 Hz |
| · Maximum input current: 8 A |
| DG-PA1000I-P-F (AC input 1): |
· Rated input voltage: 100 V
AC to 130 V AC, 50/60 Hz |
· Maximum input voltage: 90 V
AC to 143 V AC, 47 Hz to 63 Hz |
| · Maximum input current: 12 A |
| DG-PA1000I-P-F (AC input 2): |
Rated input voltage: 200 V AC
to 240 V AC, 50/60 Hz |
Maximum input voltage: 180 V
AC to 264 V AC, 47 Hz to 63 Hz |
| Maximum input current: 8 A |
Maximum output
power |
DG-PA600I-P-F: 600 W |
| DG-PA1000I-P-F: |
| 100 V AC to 130 V AC: 930 W |
| 200 V AC to 240 V AC: 1000 W |
Note: When the ambient
temperature is higher than 55°C (131°F), the maximum output power is reduced
by 50%. |
| PoE port |
Ports 1 to 48 support PoE/PoE+ (IEEE802.3af/at) power supply |
| PoE power cable pairs |
Mode A (1-2, 3-6 pairs) |
| PoE output power |
Each PoE port provides up to 30 W of power. |
The maximum power depends on
the configured power supply. |
| 1 x DG-PA600I-P-F: 370 W |
| 2 x DG-PA600I-P-F: 740 W; |
| 1 x DG-PA1000I-P-F: 740 W; |
| 2 x DG-PA1000I-P-F: 1480 W; |
a maximum output of 1440 W
over 48 ports (30 W x 48) |
Note:
The maximum number of powered devices supported by the switch is determined
by the available power of the switch and the actual power consumption of each
device. |
Maximum power
consumption |
45 W (without PoE load) |
| 1485 W (full PoE load) |
| Energy saving |
Supported |
|
|
| Dimensions and weight |
|
| Unit dimensions (W x D x H) |
442mm x 420 mm x 43.6 mm (17.40 in. x 16.53 in. x 1.72 in.) |
| Rack height |
1 RU |
| Unit weight |
4.9 kg (10.80 lbs) |
| Mounting |
Mounting on a workbench or in a rack (cabinet) |
|
|
| Environment and reliability |
|
| Temperature |
Operating temperature: -40°C to +65°C (-40°F to +149°F) at an
altitude range of 0 m to 1,800 m (0 ft. to 5,905.51 ft.) |
Note:
At an altitude between 1,800 m (5,905.51 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum
temperature decreases by 1°C (1.8°F). |
When three or four 80-km long-reach optical transceivers are configured, the
operating temperature range is –40°C to +50°C (–40°F to
+122°F). |
Storage temperature: –40°C to
+70°C (–40°F to +158°F) |
|
| Humidity |
Operating humidity: 10% to 90% RH (non-condensing) |
Storage humidity: 5% to 95% RH
(non-condensing) |
| Altitude |
Operating altitude: -500 m to +5,000 m (-1640.42 ft. to
+16,404.20 ft.) |
Storage altitude: -500 m to
+5,000 m (-1640.42 ft. to +16,404.20 ft.) |
Mean time between failure
(MTBF) |
200,253 hours (about 22 years) |
| Fan |
|
| Heat dissipation |
|
| Acoustic noise |
SPL at ambient
temperature of 27°C (80.6°F): 36 dB (30% PoE load, 2 DG-PA1000I-P-F power
modules, adjusted fan speed) |
| Power module hot swapping |
Supported |
| USB hot swapping |
Supported |
| Cable hot swapping |
Supported by all ports |
| Fan monitoring |
PID-based multi-level speed adjustment |
Fan speed control (manual
configuration not supported) |
| Fan failure alarming |
| Temperature monitoring |
Supported |
| ESD |
ESD contact/air discharge: 6 kV/8 kV |
ESD susceptibility contact/air
discharge: 8 kV/15 kV |
| Surge protection |
Service port: common mode 10 kV |
Power port: common mode 6 kV,
differential mode 6 kV |
|
|
Certifications and regulatory
compliance |
DG-S5360-48GP4X-1440W |
| Safety regulation |
IEC 62368-1 |
| EMC regulation |
EN 300386, EN 55032 ClassA, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN
61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| RoHS |
European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 |
|
|
| Software Specifications |
|
|
|
| Feature |
Description |
Ethernet
switching |
Jumbo frame (maximum length: 9,216 bytes) |
| IEEE 802.3az EEE |
| IEEE 802.1Q (4,000 VLANs) |
| Voice VLAN |
| Super VLAN and private VLAN |
MAC address-based VLAN,
interface-based VLAN, protocol-based VLAN, and IP subnet-based VLAN |
| GVRP |
| Basic QinQ |
| Selective QinQ |
| STP, RSTP, and MSTP |
| ERPS (G.8032) |
| LLDP/LLDP-MED |
| IP service |
ARP |
DHCP client, DHCP relay, and
DHCP server |
| DHCP snooping |
| DNS |
DHCPv6 client, DHCPv6 relay,
and DHCPv6 server |
| DHCPv6 snooping |
Neighbor Discovery (ND) and ND
snooping |
| IP routing |
Static routing |
| RIP and RIPng |
| OSPFv2 and OSPFv3 |
| BGP4 and BGP4+ |
| IPv4 and IPv6 VRF |
| IPv4 and IPv6 PBR |
| Multicast |
IGMP v1/v2/v3, and IGMP proxy |
| IGMP v1/v2 snooping |
| PIM-DM, PIM-SM, and PIM-SSM |
| MSDP |
| MLD v1/v2 |
| MLD snooping v1/v2 |
| PIM-SMv6 and PIM-SSM v6 |
| ACL and QoS |
Standard IP ACLs |
| Extended IP ACLs |
| Extended MAC ACLs |
| Time-based ACLs |
| Expert-level ACLs |
| ACL80 |
| IPv6 ACL |
| ACL redirection |
Traffic rate limiting on an
interface |
Congestion management: RR, SP,
WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
Congestion avoidance: tail
drop |
802.1p/DSCP/ToS traffic
classification |
Eight priority queues per
interface |
| Security |
Multiple AAA modes |
| RADIUS and TACACS+ |
Interface-based and MAC
address-based 802.1x authentication |
| Web authentication |
| HTTPS |
| SSHv1 and SSHv2 |
| Global IP-MAC binding |
Port isolation and port
security |
| IP source guard |
| SAVI |
| CPP and NFPP |
| Reliability |
REUP, RLDP, DLDP |
| IPv4 VRRP v2/v3 and IPv6 VRRP |
| BFD |
Link tracing, fault
notification, and remote loopback based on 802.3ah (EFM) |
| Dual-boot redundancy |
| Fan speed adjustment |
| Fan fault alarm |
| Device virtualization |
Virtual Switching Unit (VSU) |
NMS and
maintenance |
SPAN, RSPAN |
| sFlow |
| NTP and SNTP |
| FTP and TFTP |
| SNMP v1/v2/v3 |
| RMON (1, 2, 3, 9) |
| NETCONF |
| CWMP (TR-069) |
| gRPC |
| PoE |
IEEE 802.3af and 802.3at |
| Warm start |
| Interface priority |