10G 24 ports ethernet switch 4 SFP+
DG-S5310-24G4X
Key points
- Switch 10GB 24 ports
- 128 Gbps Capacity
- 24 gigabit ethernet ports
- 4 SFP+ 10G ports
- Redundant power supply
- L3 manageable switch
- Openflow SDN compatible
The Perfect Switch for Enterprise
The Data General DG-S5310-24G-4X 10G 24 ports switch offers a superb price/performance ratio with three standout features: 24 gigabit Ethernet ports, 4 SFP+ 10 Gbps ports, and a hot-swappable redundant power supply.
These features make it ideal for various enterprise applications. Its stability and high switching capacity ensure optimal performance, while the dual power supply guarantees uninterrupted, fail-safe operation. The 4 SFP+ 10 Gbps ports enable both stacking and high-speed connections across different areas of the enterprise.
- Switch 10GB 24 ports.
- High-capacity ports: 24 1 Gbps Ethernet ports.
- Optical ports: 4 x 10G SFP+ for uplink.
- VSU virtualization, flexible networks and high performance.
- Network security policies and real-time monitoring, providing robustness to the network.
- Abundant QoS policies for flexible resource allocation, eliminating possible congestion.
- Intelligent speed regulation, automatic port suspension, energy saving.
- Multiple management modes, simplified and easy network maintenance.
Hardware Specifications | DG-S5310-24G4X | |
---|---|---|
Interface Specifications | ||
Fixed port | 24 x 10/100/1000 BASE-T ports | |
4 x 1G/10G SFP+ ports | ||
Power module | 2 x power modules (1+1 redundancy of power modules) | |
Management port | 1 x MGMT port, 1 x console port, and 1 x USB 2.0 port | |
System Specifications | ||
Switching Capacity | 128 Gbps | |
Packet Forwarding Rate | 96 Mpps | |
Number of MAC addresses | 32 | |
ARP table size | 4k/16k (authorized) | |
ND table size | 2k/8k (authorized) | |
Number of IPv4 unicast routes | 8k/12k (authorized) | |
Number of IPv4 multicast routes | 2.5 | |
Number of IPv6 unicast routes | 4 | |
Number of IPv6 multicast routes | 1.2 | |
Number of ACEs | Ingress: 3,500 | |
Egress: 1,500 | ||
Number of IGMP groups | 2.5 | |
Number of MLD groups | 1 | |
Number of VSU members | 4 | |
Dimensions and Weight | ||
Dimensions (W x D x H) | 442 mm x 420 mm x 43.6 mm (17.40 in. x 16.56 in. x 1.72 in.), 1 RU | |
Weight | 4.2 kg (9.26 lbs) | |
CPU and Storage | ||
CPU | 1.2 GHz dual-core processor | |
BOOTROM | 16 MB | |
Flash | 2 GB | |
SDRAM | 1 GB | |
Power and Consumption | ||
Maximum power consumption | ≤ 40 W | |
Maximum output power | DG-PA70IB: 70 W | |
DG-PA150IB-F: 150 W | ||
DG-PD150IB-F: 150 W | ||
Rated input voltage | DG-PA70IB: 100 V AC to 240 V AC | |
DG-PA150IB-F: 100 V AC to 240 V AC | ||
DG-PD150IB-F: -48 V DC to -60 V DC | ||
Maximum input voltage | DG-PA70IB: 90 V AC to 264 V AC, 50 Hz to 60 Hz | |
DG-PA150IB-F: 90 V AC to 264 V AC, 50 Hz to 60 Hz | ||
DG-PD150IB-F: -75 V DC to -36 V DC | ||
Environment and Reliability | ||
MTBF | 44.03 years (dual power modules) 24.85 years (single power module) | |
Primary airflow | Left/Front-to-rear airflow | |
Operating temperature | 0°C to 45°C (32°F to 113°F) | |
Storage temperature | –40°C to +70°C (–40°F to +158°F) | |
Operating humidity | 10% to 90% RH (non-condensing) | |
Storage humidity | 5% to 95% RH (non-condensing) | |
Operating altitude | 0 m to 5000 m (16404.20 ft.) | |
Operating noise | < 56.5 dB | |
Interface suDGe protection | Power port: 6 kV | |
Telecom port: 10 kV (MGMT port: 4 kV) | ||
Software Specifications | ||
DG-S5310-E Series | ||
Feature | Description | |
Ethernet Switching | IEEE 802.1Q (supporting 4K VLANs) | |
Jumbo frame (maximum length: 9,216 bytes) | ||
Maximum number of VLANs that can be created: 4,094 | ||
Voice VLAN | ||
Super VLAN and private VLAN | ||
MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment | ||
GVRP | ||
Basic QinQ and selective QinQ | ||
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) | ||
Auto errdisable recovery | ||
BPDU filter | ||
BPDU guard | ||
Port fast | ||
Root guard | ||
ERPS (G.8032) | ||
LLDP/LLDP-MED, LLDP IPv6, and LLDP-POE | ||
IP Service | Static and dynamic ARP, ARP proxy, and ARP entry timeout | |
DHCP client, DHCP relay, DHCP server, and DHCP snooping | ||
DHCPv6 client, DHCPv6 relay, DHCPv6 server, and DHCPv6 snooping | ||
DNS client, DNS proxy, and DNSv6 client | ||
MAC address filtering | ||
Setting the MAC address aging time | ||
Neighbor Discovery (ND), ND proxy, and ND snooping | ||
GRE tunnel | ||
IP Routing | IPv4 and IPv6 static routing | |
RIP and RIPng | ||
OSPFv2, OSPFv3, and GR | ||
IS-ISv4 and IS-ISv6 | ||
BGP4 and BGP4+ | ||
IPv4/IPv6 VRF | ||
IPv4/IPv6 PBR | ||
Multicast | IGMPv1/v2/v3 | |
IGMPv1/v2 snooping | ||
IGMP fast leave | ||
PIM-DM, PIM-SM, PIM-SSM, PIM SMv6, and PIM-SSMv6 | ||
MSDP for inter-domain multicast | ||
MLDv1/v2 and MLD proxy | ||
MLDv1/v2 snooping | ||
PIM-SMv6 | ||
Multicast source IP address check | ||
Multicast source port check | ||
Multicast querier | ||
ACL and QoS | Standard IP ACLs (hardware ACLs based on IP addresses) | |
Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers) | ||
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) | ||
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) | ||
Time based ACLS, ACL 80, and IPv6 ACL | ||
Global ACLs | ||
ACL redirection | ||
Port traffic identification | ||
Port traffic rate limiting | ||
802.1p/DSCP/ToS traffic classification | ||
Congestion management: SP, WRR, DRR, WFQ, SP+WFQ, SP+WRR, SP+DRR, and SP+WFQ | ||
Congestion avoidance: tail drop, RED, and WRED | ||
Eight priority queues per port | ||
Rate limiting in each queue | ||
Security | Multiple AAA modes | |
RADIUS authentication and authorization | ||
RADIUS and TACACS+ | ||
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication | ||
Web authentication | ||
Hypertext Transfer Protocol Secure (HTTPS) | ||
SSHv1 and SSHv2 | ||
Global IP-MAC binding | ||
ICMPv6 | ||
Port security | ||
IP source guard | ||
SAVI | ||
ARP spoofing prevention | ||
CPP and NFPP | ||
Multiple attack defense functions | ||
3-tuple binding (IP address, MAC address, and port) | ||
3-tuple binding (IPv6 address, MAC address, and port) | ||
Filtering of invalid MAC addresses | ||
Port- and MAC address-based 802.1x authentication | ||
MAB authentication | ||
Portal authentication and Portal 2.0 authentication | ||
ARP check | ||
DAI | ||
ARP packet rate limiting | ||
Gateway ARP spoofing prevention | ||
Broadcast storm suppression | ||
Hierarchical management of administrators and password protection | ||
BPDU guard | ||
Port protection | ||
Reliability | REUP | |
RLDP | ||
RLDP, Layer 2 link connectivity detection, and unidirectional link detection | ||
DLDP | ||
IPv4 VRRP v2/v3, IPv6 VRRP, and super-VLAN for VRRP | ||
BFD, RAS, NSR, VRRR, VRRP+, and SDN loop detection | ||
Basic LACP | ||
Inter-VSU AP | ||
Link monitoring, fault notification, and remote loopback based on 802.3ah (EFM) | ||
Hot swapping of power modules | ||
Device virtualization | VSU | |
Local and remote stacking | ||
Inter-chassis link binding in a stack | ||
Virtualization through standard service interfaces | ||
NMS and maintenance | RSPAN and ERSPAN | |
sFlow | ||
NTP client, NTP server, NTPv6 client, and NTPv6 server | ||
SNTP | ||
CLI (Telnet/Console) | ||
FTP client, FTP server, FTPv6 client, and FTPv6 server | ||
TFTP client, TFTP server, TFTPv6 client, and TFTPv6 server | ||
FTP and TFTP | ||
SNMP v1/v2/c3 | ||
Web | ||
Syslog/Debug | ||
RMON (1, 2, 3, 9) | ||
Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups | ||
RMON used to implement Ethernet statistics, historical statistics, and alarm functions | ||
NETCONF | ||
MACC | ||
CWMP | ||
gRPC | ||
OpenFlow Special 1.3 | ||
Flow table analysis defined by all protocols | ||
Transmission of specified packets to the controller | ||
Configuring the controller’s IP address and port | ||
Notifying port status changes to the controller | ||
RNS, configuration rollback, and 802.3ah | ||
1:1 mirroring | ||
N:1 mirroring | ||
1:N mirroring | ||
Flow-based local and remote mirroring | ||
VXLAN | VXLAN (authorized) | |
PoE | DG-S5310-24GP4X and DG-S5310-48GP4X: | |
IEEE 802.3af and 802.3at power supply standards | ||
Automatic and eneDGy-saving power supply management modes | ||
Uninterrupted power supply in hot start mode | ||
Scheduled power-on or power-off of PoE ports based on the time policy | ||
Port priority |